SPEDLPX0205REN
SPECIFICHE TECNICHE
TECHNICAL SPECIFICATIONS
700-3000VA SINGLE-PHASE
On line double conversion (VFI) technology
DIALOG PLUS
Vue de la page 0
1 2 3 4 5 6 ... 33 34

Résumé du contenu

Page 1 - DIALOG PLUS

SPEDLPX0205REN SPECIFICHE TECNICHE TECHNICAL SPECIFICATIONS 700-3000VA SINGLE-PHASE On line double conversion (

Page 2 - Table of contents

SPEDLPX0205REN 10DIALOG PLUS > 6.2 Rack version The rack-version UPS is supplied together with the following equipments:  UPS  IEC

Page 3 - 1 - OBJECTIVE

SPEDLPX0205REN 11DIALOG PLUS Net Adapter USB Converter Multiplexer Remote led mimic panel Battery back-up extension 7 - BLOCK DIAGRAM &g

Page 4 - 4 - CHARACTERISTICS

SPEDLPX0205REN 12DIALOG PLUS 4) Rectifier/Booster: When the mains power supply is present, this converts the mains alternating current (AC) int

Page 5

SPEDLPX0205REN 13DIALOG PLUS Operating modes "NORMAL" mode During NORMAL mode, the UPS power is taken from the incoming mains supply

Page 6

SPEDLPX0205REN 14DIALOG PLUS “Mains out of tolerance” The UPS is designed to function with a wide range of input voltages. This ensures that th

Page 7 - 5 - NORMATIVE REFERENCES

SPEDLPX0205REN 15DIALOG PLUS 8 - INTERFACING > 8.1 Serial communication port The UPS has the following communication ports (see UPS vi

Page 8

SPEDLPX0205REN 16DIALOG PLUS > 8.2 Communication software MAIN CHARACTERISTICS 1) Sequential and prioritised shutdown: PowerShield2 enabl

Page 9 - > 6.1 Tower version

SPEDLPX0205REN 17DIALOG PLUS POWERSHIELD2 SOFTWARE FUNCTIONS 1) Graphical monitoring of the UPS status PowerShield2 is the easy to use yet p

Page 10 - > 6.2 Rack version

SPEDLPX0205REN 18DIALOG PLUS > 8.3 Configuration software Configuration Software UPSTools software enables the user to configure the UPS,

Page 11 - 7 - BLOCK DIAGRAM

SPEDLPX0205REN 19DIALOG PLUS 9 - OPTIONS > 9.1 Summary table of the options available DESCRIPTION DIMENSIONS (HxWxD mm) WEIGHT ( K

Page 12

SPEDLPX0205REN 2 DIALOG PLUS Table of contents ..1.. OBJECTIVE 3 ..2.. DESCRIPTION OF THE SYSTEM 3 ..3.. APPLICATIONS 4 ..4.. CH

Page 13 - Operating modes

SPEDLPX0205REN 20DIALOG PLUS 10 - FRONT PANEL > 10.1. Display panel The LED display panel enables the user to check the UPS status a

Page 14

SPEDLPX0205REN 21DIALOG PLUS Green / Steady The UPS is operating in battery mode and the audible alarm will sound at regular intervals. Green /

Page 15 - 8 - INTERFACING

SPEDLPX0205REN 22DIALOG PLUS Table 3: input voltage Battery LED bar Input Voltage 1 2 3 4 5 190V~200V * 200V~230V * * 230V~

Page 16

SPEDLPX0205REN 23DIALOG PLUS > 10.3 UPS front view Dialog Plus 700 - 1000 - 1500VA Dialog Plus 2000 - 3000VA

Page 17

SPEDLPX0205REN 24DIALOG PLUS 11 - REAR PANEL > 11.1 Rear panel 700 – 2000 VA Models 1. RS232 serial communication port 5. IEC

Page 18

SPEDLPX0205REN 25DIALOG PLUS > 11.2 Rear panel 2000ER – 3000/3000ER VA Models 1. RS232 serial communication port 6. IEC outpu

Page 19 - 9 - OPTIONS

SPEDLPX0205REN 26DIALOG PLUS 12 TECHNICAL DATA > 12.1 Tower models MODEL POWER BACK-UP ( min ) DIMENSIONS (HxWxD mm) WEIGHT (Kg) Dia

Page 20 - > 10.1. Display panel

SPEDLPX0205REN 27 DIALOG PLUS > 12.3 Summary data sheets MODEL 700VA 1000VA 1000VA ER 1500VA 2000VA 2000VA ER 3000VA 3000VA ER INPUT

Page 21

SPEDLPX0205REN 28DIALOG PLUS MODEL 700VA 1000VA 1000VA ER 1500VA 2000VA 2000VA ER 3000VA 3000VA ER BATTERIES Back-up in minutes 8 8 Ex

Page 22

SPEDLPX0205REN 29DIALOG PLUS MODEL 700VA 1000VA 1000VA ER 1500VA 2000VA 2000VA ER 3000VA 3000VA ER Frequency variation velocity (Hz/sec.)

Page 23 - > 10.3 UPS front view

SPEDLPX0205REN 3 DIALOG PLUS 1 - OBJECTIVE This technical document has been produced to be used by UPS system designers and installers.

Page 24

SPEDLPX0205REN 30DIALOG PLUS MODEL 700VA 1000VA 1000VA ER 1500VA 2000VA 2000VA ER 3000VA 3000VA ER Depth (mm) 400 400 400 500 460 4

Page 25

SPEDLPX0205REN 31DIALOG PLUS 13 . DIALOG PLUS RACK > 13.1 Rack models MODELS FRONT VIEWS REAR VIEWS Dialog Plus Rack DLPR 700 - 1500 VA

Page 26 - 12 TECHNICAL DATA

SPEDLPX0205REN 32DIALOG PLUS > 13.2 Back-up expansion modules for rack version For types and back-up times of the Dialog Plus Rack models re

Page 27

SPEDLPX0205REN 33DIALOG PLUS Dialog Plus rack 2200VA Dialog Plus rack 2200 ER VA Dialog Plus rack 3000 / 3000 ER VA

Page 28

SPEDLPX0205REN 34DIALOG PLUS Battery Box 1 - RS232 serial communication port 3 - IEC output sockets (max 10A) 5 - IEC mains input plug

Page 29

SPEDLPX0205REN 4 DIALOG PLUS Rack version MODEL Dialog Plus rack 70 Dialog Plus rack 100 / 100 ER Dialog Plus rack 150 Dialog Plus rack 22

Page 30

SPEDLPX0205REN 5 DIALOG PLUS − Programmable timer: This function enables the user to program the timer to automatically switch the system on

Page 31 - 13 . DIALOG PLUS RACK

SPEDLPX0205REN 6 DIALOG PLUS Battery optimisation − High level of battery reliability (automatic battery test): The UPS carries out battery

Page 32 - > 13.3 Rear panel view

SPEDLPX0205REN 7 DIALOG PLUS Windows 95, 98, 2000, Windows 2003 Server, Me, Xp, NT4.0, Novell, Mac OS, Mac Osx, Mac Os 9.x & Linux operating

Page 33

SPEDLPX0205REN 8 DIALOG PLUS IEC61000-4-11: Low frequency disturbances EN50141: Induced radio interference EN55022: Radio frequency disturba

Page 34

SPEDLPX0205REN 9 DIALOG PLUS 6 - SUPPLIED EQUIPMENT AND ACCESSORIES > 6.1 Tower version The tower-version UPS is supplied together

Commentaires sur ces manuels

Pas de commentaire